Install Shutoff Valves Under a Bathroom Sink

Cut the water supply lines, dry-fit compression shutoff valves to ensure proper alignment, then tighten the compression nuts by hand plus one-quarter turn with a wrench.

Difficulty
Intermediate
Time
1 Hour
Cost
$25 - $45
Tools
Tubing cutter, Two adjustable wrenches, Deburring tool, Bucket, Rags, Marker
Permit required
No
Contractor recommended
No
You will need
Quarter-turn angle stop valves, ½-inch compression inlet (qty. 2), Braided stainless supply lines, ⅜-inch compression x ½-inch FIP (qty. 2), Tubing cutter with deburring reamer, Two adjustable wrenches, Bucket and rags, Marker or pencil, Teflon tape (for faucet connections), Flashlight or headlamp

Materials

  • 2 Quarter-turn angle stop valves, ½-inch compression inlet (Match the inlet size to your copper supply stubs—½-inch is standard for bathroom sinks, but measure to confirm) — $8 - $15 each
  • 2 Braided stainless supply lines, ⅜-inch compression x ½-inch FIP (Measure from valve outlet to faucet tailpiece and add six inches—typical lengths are 12, 16, or 20 inches) — $6 - $10 each
  • 1 roll Teflon tape or pipe thread sealant (Not needed for compression fittings themselves, but useful for the threaded supply line connections) — $2 - $4

Step by step

  1. Prep · 10 min

    Kill the Water Flow First

    Turn off the water at your home's main shutoff valve. Open the bathroom faucet and let it run until water stops flowing completely. Flush the toilet once to drain the tank. Place a bucket and towels under the work area to catch residual water in the pipes.

    Tip: Open a faucet on a floor below the bathroom to help drain stubborn standing water from the vertical supply lines.
  2. Prep · 15 min

    Square Cuts, Not Hacksaw Hacks

    Measure up from the wall escutcheon about half an inch and mark both hot and cold copper pipes. Use a tubing cutter to make clean, square cuts at both marks. Rotate the cutter around the pipe, tightening a quarter-turn after each full rotation. Clean cuts prevent leaks—hacksaw cuts leave burrs that interfere with compression seals.

    Tip: Keep a rag handy to catch the small amount of water that will dribble out when you complete each cut.
  3. Prep · 5 min

    Smooth Edges Save Seals

    Use the reamer blade on the tubing cutter or a deburring tool to smooth the inside edge of each cut pipe. Wipe both pipe ends completely dry with a clean rag. Any moisture, oxidation, or debris will prevent proper compression seal.

    Tip: Run your finger inside the pipe end—if you feel a sharp edge, deburr again until it's smooth.
  4. Assembly · 5 min

    Order Matters—Nut Then Ferrule

    On each pipe, slide the compression nut over the pipe first, threads facing out, then slide the brass ferrule (the small ring) onto the pipe behind it. This order matters—you cannot add the nut after the valve is on.

    Tip: Set the hardware for both valves at once so you don't forget which pipe still needs parts.
  5. Assembly · 10 min

    Position Outlets for Easy Connection

    Slide the angle stop valve body onto each pipe until it seats against the wall escutcheon. The outlet should point downward toward where the supply line will connect. Hold the valve body steady and hand-tighten the compression nut until it stops. The ferrule should now be captured between the nut and the valve body.

    Tip: Orient both valve handles in the same direction for a cleaner look and easier operation.
  6. Installation · 10 min

    Snug—Not Vise-Grip Tight

    Hold the valve body with one wrench to keep it from rotating. Use a second wrench to tighten the compression nut about a quarter turn past hand-tight. Stop there. The ferrule is now biting into the copper and forming the seal. Do not overtighten.

    Tip: If the nut spins freely without resistance, you've stripped it or the ferrule wasn't seated—back off and start that valve over.
  7. Testing · 10 min

    Verify Every Joint Holds

    Turn both new valves to the closed position. Go turn on the main water supply slowly. Return to the bathroom and inspect both compression fittings for leaks. If you see water beading at the nut, tighten it another eighth-turn. If it still leaks after a quarter-turn total, you've likely overtightened and damaged the ferrule.

    Tip: Dry the fittings completely with a rag before you turn the water on so you can see new moisture immediately.
  8. Final · 10 min

    Link Valves to Faucet Safely

    Attach flexible braided supply lines from each valve outlet to the faucet tailpieces. Hand-tighten, then snug with a wrench. Turn each angle stop to the on position. Check all connections—valve bodies, supply line ends at the valves, and supply line connections at the faucet—for leaks. Wipe dry and monitor for ten minutes.

    Tip: Buy supply lines six inches longer than you think you need—the extra length makes installation easier and prevents kinking.

Questions people ask

Can I reuse the compression ferrule if I need to remove the valve?

No. Once a brass ferrule compresses onto copper pipe, it deforms permanently to match that exact section of pipe. Removing and reinstalling it will not seal properly. Always replace the ferrule if you remove a compression valve for any reason.

Do I need to use Teflon tape on compression fittings?

No. Compression fittings seal with mechanical pressure from the ferrule biting into the pipe, not with thread sealant. Teflon tape on the threads can actually prevent proper tightening. Save the tape for the threaded connections where you attach the supply lines to the faucet.

What's the difference between angle stops and straight stops?

Angle stops have the outlet at a 90-degree angle to the inlet, which works when supply pipes come out of the wall. Straight stops have inline inlets and outlets, used when pipes come up through the floor. Bathroom sinks almost always use angle stops because the supplies come through the wall behind the vanity.

Troubleshooting

Compression nut spins freely without tightening

The ferrule isn't seated properly or the pipe wasn't cut square. Remove the valve, inspect the ferrule for damage, replace it if needed, and ensure the pipe end is perpendicular and deburred.

Water leaks from around the compression nut after tightening

Try tightening another eighth-turn. If it still leaks after a total quarter-turn with a wrench, you've likely overtightened and crushed the ferrule—remove everything, replace the ferrule, and start over with less force.

Not enough pipe sticking out from the wall to attach the valve

You need at least half an inch of clean copper past the escutcheon. If the stub is too short, you'll need to remove the escutcheon and work with the pipe inside the wall, or install a slip-joint extension.

Valve handle is upside down or pointing the wrong direction

Loosen the compression nut completely, rotate the valve body to the desired orientation, and retighten. Do this before you connect the supply lines.

Water continues to drip from faucet when new valves are closed

Quarter-turn valves seat with a 90-degree turn—make sure the handle is perpendicular to the pipe. If it still leaks through when closed, the valve seat is damaged and the valve needs replacement.

Related work under the sink: replace a water supply line, the bathroom install guides and the plumbing trade guides.